Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
2.
J Imaging Inform Med ; 2024 Mar 14.
Artigo em Inglês | MEDLINE | ID: mdl-38483695

RESUMO

The introduction of three-dimensional (3D) printed anatomical models has garnered interest in pre-operative planning, especially in orthopedic and trauma surgery. Identifying potential error sources and quantifying their effect on the model dimensional accuracy are crucial for the applicability and reliability of such models. In this study, twenty radii were extracted from anatomic forearm specimens and subjected to osteotomy to simulate a defined fracture of the distal radius (Colles' fracture). Various factors, including two different computed tomography (CT) technologies (energy-integrating detector (EID) and photon-counting detector (PCD)), four different CT scanners, two scan protocols (i.e., routine and high dosage), two different scan orientations, as well as two segmentation algorithms were considered to determine their effect on 3D model accuracy. Ground truth was established using 3D reconstructions of surface scans of the physical specimens. Results indicated that all investigated variables significantly impacted the 3D model accuracy (p < 0.001). However, the mean absolute deviation fell within the range of 0.03 ± 0.20 to 0.32 ± 0.23 mm, well below the 0.5 mm threshold necessary for pre-operative planning. Intra- and inter-operator variability demonstrated fair to excellent agreement for 3D model accuracy, with an intra-class correlation (ICC) of 0.43 to 0.92. This systematic investigation displayed dimensional deviations in the magnitude of sub-voxel imaging resolution for all variables. Major pitfalls included missed or overestimated bone regions during the segmentation process, necessitating additional manual editing of 3D models. In conclusion, this study demonstrates that 3D bone fracture models can be obtained with clinical routine scanners and scan protocols, utilizing a simple global segmentation threshold, thereby providing an accurate and reliable tool for pre-operative planning.

3.
3D Print Med ; 10(1): 5, 2024 Feb 20.
Artigo em Inglês | MEDLINE | ID: mdl-38376810

RESUMO

BACKGROUND: Additively manufactured (AM) anatomical bone models are primarily utilized for training and preoperative planning purposes. As such, they must meet stringent requirements, with dimensional accuracy being of utmost importance. This study aimed to evaluate the precision and accuracy of anatomical bone models manufactured using three different AM technologies: digital light processing (DLP), fused deposition modeling (FDM), and PolyJetting (PJ), built in three different part orientations. Additionally, the study sought to assess surgeons' perceptions of how well these models mimic real bones in simulated osteosynthesis. METHODS: Computer-aided design (CAD) models of six human radii were generated from computed tomography (CT) imaging data. Anatomical models were then manufactured using the three aforementioned technologies and in three different part orientations. The surfaces of all models were 3D-scanned and compared with the original CAD models. Furthermore, an anatomical model of a proximal femur including a metastatic lesion was manufactured using the three technologies, followed by (mock) osteosynthesis performed by six surgeons on each type of model. The surgeons' perceptions of the quality and haptic properties of each model were assessed using a questionnaire. RESULTS: The mean dimensional deviations from the original CAD model ranged between 0.00 and 0.13 mm with maximal inaccuracies < 1 mm for all models. In surgical simulation, PJ models achieved the highest total score on a 5-point Likert scale ranging from 1 to 5 (with 1 and 5 representing the lowest and highest level of agreement, respectively), (3.74 ± 0.99) in the surgeons' perception assessment, followed by DLP (3.41 ± 0.99) and FDM (2.43 ± 1.02). Notably, FDM was perceived as unsuitable for surgical simulation, as the material melted during drilling and sawing. CONCLUSIONS: In conclusion, the choice of technology and part orientation significantly influenced the accuracy and precision of additively manufactured bone models. However, all anatomical models showed satisfying accuracies and precisions, independent of the AM technology or part orientation. The anatomical and functional performance of FDM models was rated by surgeons as poor.

4.
J Mech Behav Biomed Mater ; 150: 106259, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38039773

RESUMO

The response of bone tissue to mechanical load is complex and includes plastic hardening, viscosity and damage. The quantification of these effects plays a mayor role in bone research and in biomechanical clinical trials as to better understand related diseases. In this study, the damage growth in individual wet human trabeculae subjected to cyclic overloading is quantified by inverse rheological modeling. Therefore, an already published rheological material model, that includes linear elasticity, plasticity and viscosity is extended by a damage law. The model is utilized in an optimization process to identify the corresponding material parameters and damage growth in single human trabeculae under tensile load. Results show that the damage model is leading to a better fit of the test data with an average root-mean-square-error (RMSE) of 2.52 MPa compared to the non-damage model with a RMSE of 3.03 MPa. Although this improvement is not significant, the damage model qualitatively better represents the data as it accounts for the visible stiffness reduction along the load history. It returns realistic stiffness values of 11.92 GPa for the instantaneous modulus and 5.73 GPa for the long term modulus of wet trabecular human bone. Further, the growth of damage in the tissue along the load history is substantial, with values above 0.8 close to failure. The relative loss of stiffness per cycle is in good agreement with comparable literature. Inverse rheological modeling proves to be a valuable tool for quantifying complex constitutive behavior from a single mechanical measurement. The evolution of damage in the tissue can be identified continuously over the load history and separated from other effects.


Assuntos
Osso e Ossos , Osso Esponjoso , Humanos , Estresse Mecânico , Elasticidade , Reologia , Fenômenos Biomecânicos
5.
Mult Scler Relat Disord ; 74: 104675, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37121104

RESUMO

BACKGROUND: Vascular disease risk factors (VDRF) such as hypertension, hyperlipidemia, obesity, diabetes and heart disease likely play a role in disease progression in people with multiple sclerosis (PwMS) (Marrie, Rudick et al. 2010). Studies exploring the mechanistic connection between vascular disease and MS disease progression are scant. We hypothesized that phosphate energy metabolism impairment in PwMS with VDRFs (VDRF+) will be greater compared to PwMS without VDRFs (VDRF-) and is related to increased brain atrophy in VDRF+. To test this hypothesis, we planned to study the differences in the high energy phosphate (HEP) metabolites in cerebral gray matter as assessed by 31P magnetic resonance spectroscopic imaging (MRSI) and MRI brain volumetric in the VDRF+ and VDRF- PwMS at four different timepoints over a 3 yearlong period using a 7T MR system. We present here the results from the cross-sectional evaluation of HEP metabolites and brain volumes. We also evaluated the differences in clinical impairment, blood metabolic biomarkers and quality of life in VDRF+ and VDRF- PwMS in this cohort. METHODS: Group differences in high energy phosphate metabolites were assessed from a volume of interest in the occipital region using linear mixed models. Brain parenchymal and white matter lesion volumes were determined from MR anatomic images. We present here the cross-sectional analysis of the baseline data collected as part of a longitudinal 3 yearlong study where we obtained baseline and subsequent 6-monthly clinical and laboratory data and annual 7T MRI volumetric and 31P MR spectroscopic imaging (MRSI) data on 52 PwMS with and without VDRF. Key clinical and laboratory outcomes included: body mass index (BMI), waist and thigh circumferences and disability [Expanded Disability Status Scale (EDSS)], safety (complete blood count with differential, complete metabolic), lipid panel including total cholesterol and HbA1C. We analyzed clinical and laboratory data for the group differences using student's t or χ2 test. We investigated relationship between phosphate metabolites and VDRF using mixed effect linear regression. RESULTS: Complete MRI data were available for 29 VDRF+, age 56.3 (6.8) years [mean (SD)] (83% female), and 23 VDRF-, age 52.5 (7.5) years (57% female) individuals with MS. The mean value of normalized adenosine triphosphate (ATP) (calculated as the ratio of ATP to total phosphate signal in a voxel) was decreased by 4.5% (p < .05) in VDRF+ compared to VDRF- MS group. White matter lesion (WML) volume fraction in VDRF+ individuals {0.007 (0.007)} was more than doubled compared to VDRF- participants {0.003 (0.006), p= .02}. CONCLUSIONS: We found significantly lower brain ATP and higher inorganic phosphate (Pi) in those PwMS with VDRFs compared to those without. ATP depletion may reflect mitochondrial dysfunction. Ongoing longitudinal data analysis from this study, not presented here, will evaluate the relationship of phosphate metabolites, brain atrophy and disease progression in PwMS with and without vascular disease.


Assuntos
Esclerose Múltipla Crônica Progressiva , Esclerose Múltipla , Doenças Vasculares , Humanos , Feminino , Pessoa de Meia-Idade , Masculino , Esclerose Múltipla/diagnóstico por imagem , Esclerose Múltipla/patologia , Estudos Transversais , Qualidade de Vida , Encéfalo/diagnóstico por imagem , Encéfalo/patologia , Esclerose Múltipla Crônica Progressiva/patologia , Imageamento por Ressonância Magnética/métodos , Progressão da Doença , Fosfatos , Atrofia/patologia , Fatores de Risco
7.
BMJ Case Rep ; 11(1)2018 Nov 28.
Artigo em Inglês | MEDLINE | ID: mdl-30567127

RESUMO

We report a case of a progressive supranuclear palsy-like phenotype with rapidly progressive dementia and prominent language and executive dysfunction. Pathological examination revealed no midbrain or white matter tauopathy, but rather chronic meningoencephalitis and other mixed pathology. The cerebrospinal fluid (CSF) in this case showed a novel antibody against central nervous system and renal tissue.


Assuntos
Encéfalo/patologia , Demência/diagnóstico , Meningoencefalite/patologia , Paralisia Supranuclear Progressiva/patologia , Proteínas tau/metabolismo , Idoso , Anticorpos/imunologia , Formação de Anticorpos/imunologia , Autopsia/métodos , Encéfalo/diagnóstico por imagem , Evolução Fatal , Humanos , Imageamento por Ressonância Magnética/métodos , Masculino , Meningoencefalite/diagnóstico por imagem , Meningoencefalite/imunologia , Fenótipo , Tomografia por Emissão de Pósitrons , Paralisia Supranuclear Progressiva/líquido cefalorraquidiano , Paralisia Supranuclear Progressiva/diagnóstico por imagem , Paralisia Supranuclear Progressiva/imunologia
8.
Sci Rep ; 8(1): 15440, 2018 10 18.
Artigo em Inglês | MEDLINE | ID: mdl-30337675

RESUMO

Multiple GWAS studies have shown that the SNP rs2281808 TT variant, present within the SIRPG gene, is associated with autoimmune diseases, such as type 1 diabetes. However, the role of SIRPγ in human T-cells is not known, neither is the functional significance of TT variant. Here we investigated SIRPG genotypes and their effects on the fate and function of human T-cells. We found that the presence of T variant resulted in reduction of SIRPγ expression on T-cells. Functionally, SIRPγlow CD8 T-cells in CT and TT individuals existed in a heightened effector state with lower activation threshold and had greater expression of genes and molecules associated with migratory and cytotoxic potential. Further, SIRPγlow CD8 T-cells were deficient in transcription factors associated with long-term functional memory formation. Our study reveals biological consequences of the SNP rs2281808 and provides novel insights into the potential mechanisms by which SIRPγ might regulate human immune responses.


Assuntos
Antígenos de Diferenciação/genética , Linfócitos T CD8-Positivos/metabolismo , Polimorfismo de Nucleotídeo Único , Receptores Imunológicos/genética , Subpopulações de Linfócitos T/metabolismo , Adulto , Idoso , Antígenos de Diferenciação/biossíntese , Antígenos de Diferenciação/fisiologia , Autoimunidade/genética , Linfócitos T CD8-Positivos/imunologia , Citotoxicidade Imunológica , Feminino , Regulação da Expressão Gênica , Genótipo , Humanos , Memória Imunológica/genética , Ativação Linfocitária , Masculino , Pessoa de Meia-Idade , Receptores Imunológicos/biossíntese , Receptores Imunológicos/fisiologia , Subpopulações de Linfócitos T/imunologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...